Where Do You Need Fire Doors?

Fire doors are an important component of any building's fire safety precautions. They are specially designed doors that can withstand fire and smoke for a certain amount of time, allowing time for people to escape the building safely if a fire breaks out. But where exactly do you need fire doors?

Knowing where fire doors are needed is key for safety and compliance in any property. These doors are required in certain areas of commercial, residential, and public buildings to prevent the spread of fire and protect occupants. Let’s take a closer look at some common locations where fire doors are necessary. This guide clearly explains where fire doors should be placed, helping you meet safety standards and keep people safe.

Key Takeaways

  1. Fire doors are a legal requirement in commercial, public, and multi-occupied residential buildings to stop fire spreading, protect escape routes, and ensure occupant safety.
  2. Under the Regulatory Reform (Fire Safety) Order 2005, regular maintenance and inspection of fire doors is required, and significant penalties are imposed for non-compliance.
  3. Professional installation and routine inspections are essential for the effective performance of fire doors, with specific ratings and materials to meet various fire resistance needs.

Do All Buildings Need Fire Doors?

Fire doors are a legal obligation in non-domestic properties such as commercial premises, public buildings, and multiple occupancy residential buildings like flats and HMOs. These doors are designed to contain fire in one part of the building, limiting damage and protecting escape routes. The necessity of fire doors varies depending on the building type and its specific fire safety requirements.

The installation of fire doors is mandatory in commercial and public buildings, as well as multi-occupied residential structures, to ensure the safety of occupants and provide clear escape routes in case of fire. Understanding where and why these doors are required helps in effectively planning and implementing fire safety measures. Let’s take a closer look at different building types and the specific requirements for fitting fire doors.

Commercial Buildings

Commercial buildings are obliged to comply with strict fire safety standards, which include the installation of fire doors. For new commercial premises in the UK, fire doors are required according to the compartmentation plan outlined in the government’s fire safety Document B. These doors are mandated to provide at least 30 minutes of fire resistance and need to include intumescent seals and self-closing mechanisms.

The strategic placement of internal fire doors in commercial buildings depends on the structure’s design, including escape routes and the developed fire evacuation strategy. Internal doors, especially those leading to corridors and stairways, must be fitted with fire doors to ensure a clear and safe escape path during emergencies.

Residential Requirements:

In blocks of flats and houses of multiple occupancy (HMOs), installing fire doors is essential for safety. These doors should be placed in any shared or communal area, and at the entrances of individual flats to help contain fires and provide residents with a safe escape route if needed.

Special attention is given to taller buildings; for residential structures in England over 11 meters, the Fire Safety (England) Regulations 2022 require regular inspections of fire doors to ensure they work properly. This highlights the importance of keeping fire safety measures effective in homes.

Individual private homes, such as single-family houses, are generally exempt from the requirement to have fire doors. The regulations primarily focus on communal areas in residential buildings and non-domestic properties. All newly constructed or renovated homes with more than three stories (including loft conversions) are required to have fire doors installed. These doors should be placed in every living space that connects to a stairwell. Additionally, any home with a door leading to an internal garage must also be equipped with a fire door.

Public Spaces

The Fire Safety Order requires schools, hospitals, government offices, and other public buildings to maintain and properly function fire doors. These areas typically have high foot traffic and require fast and safe evacuation in an emergency. Fire doors not only help contain fires but also protect people from toxic smoke that can cause harm or make it difficult to escape.

In addition to fire doors, public spaces must have clearly marked escape routes and emergency lighting for visibility. These safety measures must also be regularly inspected to ensure they are effective in case of a fire.

Where Is A Fire Door Required?

Recognising the important areas for fire door installation is key to devising an effective fire safety strategy. Fire doors serve as a vital part of an escape route by containing fires within a designated area and limiting the spread of fire and smoke. The specific placement of fire doors is often informed by a comprehensive fire risk assessment, which identifies the unique fire risks present in a building and dictates where fire doors should be installed. By compartmentalising a building, fire doors effectively contain fire and smoke within designated areas, thereby safeguarding evacuation routes for all occupants.

Non-Domestic Buildings

  1. Escape Routes: Fire doors are required on all internal doors leading to corridors and stairways, enabling clear escape paths while preventing fire from restricting access to emergency exits.
  2. High-Risk Areas: Spaces with a higher likelihood of fire incidents, such as IT server rooms and boiler rooms, necessitate the installation of fire doors to mitigate risks.

Residential Buildings

  1. Blocks of Flats and HMOs: Fire doors are essential at entrance points to communal areas and for flat entrance doors that open into common parts.
  2. Buildings Over Three Storeys: In residential structures comprising three or more storeys, fire doors must be positioned between any habitable room and stairwells, as well as between a house and an integral garage.
  3. Private Residences: For a single domestic dwelling, fire doors are typically not required unless the property has a second-floor escape route (e.g. loft conversion).

Mixed-Use Buildings

  1. Separation of Spaces: Fire doors are crucial in separating residential and commercial areas to enhance safety and fire protection.

Integration of Fire Doors in Existing Structures

Integrating fire doors into existing buildings presents specific challenges. From design and material selection to installation, the process requires careful planning and consideration.

Fire risk assessments are essential to determining the type and placement of fire doors. They also check whether current door frames can support fire-rated doors and meet fire safety regulations.

Existing timber door frames can be retrofitted with certified fire doors by observing the specifications provided by manufacturers or certification schemes. Regular inspections of fire doors include assessments of:

  1. the frame
  2. door integrity
  3. hardware
  4. seals
  5. the correct operation of the assembly

These inspections are required to ensure compliance and detect when replacements are needed due to factors like damage or updates in safety codes.

Compatibility with Existing Frames

Before installing fire doors in existing structures, it’s important to determine the compatibility of frames. If the frame is not suitable for a fire door, the surrounding structure may require modifications for proper installation.

A skilled inspector can assess an existing door frame to check if it is suitable for a fire door. Fire door manufacturers provide certification and product data sheets that outline the necessary specifications for compatible door frames, including size, material density, and installation requirements.

Upgrading Standard Doors

Upgrading standard internal doors to fire doors may require:

  1. Bespoke solutions or adjustments to existing frames
  2. Fire-rated doors constructed with a dense fire-resistant core material offering enhanced protection compared to standard doors
  3. Consideration that fire doors are thicker than standard doors, which might lead to challenges fitting them into existing door frames.

In some cases, bespoke fire doors may be necessary to fit fire doors into existing frames since excessive trimming of standard-sized doors can invalidate the fire performance certification. FD30 fire doors without intumescent seals can sometimes be used to upgrade standard doors. It is vital to preserve the fire door’s performance during an upgrade by maintaining correct gap sizes around the door and adhering to trimming allowances.

Fire Door Regulations: A Closer Look

Fire door regulations assign the responsibility for fire door maintenance and fire safety standards compliance to building operators. Employers, building operators, building owners, or agents are designated as ‘responsible persons’ with a legal duty to maintain fire doors regularly and oversee inspection schemes. This ‘responsible person’ is accountable for the building’s day-to-day fire safety management, including ensuring regular fire door inspections and maintenance activities.

The presence of fire doors in a building is contingent upon the building’s type, with fire doors required in commercial, public buildings, and multi-occupied residential buildings, and on whether the building has undergone extensive renovations or contains multiple dwellings. Buildings that need fire doors must be appropriately installed with compatible hardware and frames, using materials that have been tested and certified for fire resistance to meet compliance standards. Excluding private homes, all existing buildings are mandated by the Regulatory Reform (Fire Safety) Order 2005 to maintain and install fire doors properly.

Failing to adhere to fire safety regulations can result in varying levels of legal penalties, ranging from fines up to £5,000 for minor breaches to potentially unlimited fines and a maximum of 2 years in prison for major offences. The law mandates regular maintenance and inspection of fire doors to ensure they meet established safety standards and are functioning correctly, highlighting the gravity of compliance.

Non-compliance not only jeopardises the safety of occupants but also exposes building operators to significant legal and financial repercussions. Regular inspections and maintenance are necessary to avoid these penalties and ensure the safety of the building’s occupants.

Regulatory Reform (Fire Safety) Order 2005

The Regulatory Reform (Fire Safety) Order 2005 covers all business premises, public buildings, and communal areas within residential buildings, mandating fire safety practices, including the installation and maintenance of fire doors. A designated ‘Responsible Person’ must be appointed for each such commercial or public buildings building, who is accountable for complying with the fire safety aspects mandated by The Regulatory Reform (Fire Safety) Order 2005.

Under this legislation, it is compulsory for all fire doors to be maintained in an efficient working state, ensuring they are capable of performing their intended fire-resisting functions. The local fire and rescue authority can issue various notices, including:

  1. Informal notices
  2. Alteration notices
  3. Enforcement notices
  4. Prohibition notices

These notices are issued when fire safety measures do not meet the required standards.

Professional Installation and Regular Inspections

Fire doors fitted in commercial and public buildings must be installed by a competent person according to Article 17 of the Regulatory Reform (Fire Safety) Order 2005. This is to ensure compliance with fire safety regulations and to protect the occupants of the building. This ensures that fire doors are fitted correctly and form an effective part of the passive fire protection system in an emergency.

Importance of Professional Fire Door Installation

While no formal legal qualification is specifically required, a certain level of expertise is essential. Many fire door installers pursue certifications like the BM Trada Q-Mark, which verifies their skills and knowledge in proper fire door installation. These certifications often come from specific training courses that address the installation requirements.

Each fire door is accompanied by detailed installation instructions that must be followed precisely. Since the installation process can differ based on the door’s construction and the environment, adhering to these guidelines is crucial to guarantee that the fire door functions correctly in the event of a fire. Alterations to fire doors, such as trimming, must adhere to the limitations specified in the ‘Certifire Approval’ documents to ensure the doors do not lose their fire protection capabilities.

Schedule for Fire Door Inspections

Fire doors should be inspected at least once every six months to maintain their integrity and functionality. Doors located in high-traffic areas demand more frequent checks beyond the general six-month period due to increased wear and potential safety risks. In multi-occupied residential buildings over 11 meters in height, fire doors in communal areas must be inspected every three months, and flat entrance doors annually.

Conducting regular inspections of fire doors is not only a matter of safety but also a legal requirement under the Regulatory Reform (Fire Safety) Order 2005. These inspections help ensure that fire doors remain in good working condition and are capable of providing the necessary protection in the event of a fire.

Selecting the Correct Fire Door

Choosing the appropriate fire door requires an understanding of fire door ratings, materials, and aesthetics. Guidance is necessary for choosing the correct fire doors based on different building areas and their specific needs. Fire doors come with different resistance ratings, like FD30, indicating 30 minutes of fire resistance, and FD30S also includes smoke protection. Fire doors are commonly made of a solid timber core but can also be made using steel, aluminium, or gypsum to meet specific fire-resistant requirements.

Ceramic or borosilicate glass is used in fire doors thanks to its higher fire resistance compared to conventional glass. By understanding these ratings and materials, you can select the perfect fire door that meets both safety and design requirements.

Understanding Fire Door Ratings

A specially constructed door to delay the passage of flames and smoke in a fire event is commonly classified as FD30, indicating its fire resistance capability. The FD30 rating on a fire door certifies that the door can resist fire for no less than 30 minutes, as verified by manufacturer testing. While standard fire doors are rated for 30 or 60 minutes, higher resistance levels, like those of some steel doors rated for up to 4 hours, are available for specific needs.

Fire doors are rated in time increments, such as:

  1. FD20
  2. FD30
  3. FD45
  4. FD60
  5. FD90

Each rating indicates the minimum time the door can withstand fire. Selecting a fire-rated door with the appropriate rating for your building’s requirements is crucial for ensuring effective fire safety.

Matching Fire Doors to Decor

Fire doors are integral to building safety but can also be selected to match the interior design, ensuring aesthetic appeal alongside compliance with safety regulations. A variety of finishes are available for fire doors, allowing them to blend in seamlessly with the building’s existing design elements. Some options include:

  1. Wood veneer finishes
  2. Laminate finishes
  3. Painted finishes
  4. Glass panel finishes

By choosing the right design and finish, fire doors can complement the decor while providing the necessary fire resistance. This ensures that fire safety measures do not detract from the overall aesthetics of the space.

fire door inspection

Common Misconceptions About Fire Doors

  1. Fire-Resistant Paint Converts Doors: A prevalent myth is that applying fire-resistant paint to a standard door can create a fire door. This is untrue; fire doors must be crafted from specific materials and built to meet rigorous standards, with paint providing no adequate protection.
  2. Anyone Can Install a Fire Door: There is a misunderstanding that any individual can install a fire door. Proper installation is essential to ensure functionality during emergencies, meaning only trained professionals should undertake this task to comply with legal and safety regulations.
  3. Gap Size Doesn’t Matter: Some believe that the gap between a fire door and its frame is insignificant. However, this gap is essential for preventing the passage of smoke and toxic gases, with a recommended clearance of around 3mm.
  4. Documentation Is Not Important: It is mistakenly assumed that fire door documentation is unnecessary. Each fire door should possess a certification label and an accredited test certificate to validate its compliance with fire safety standards.
  5. Standard Doors Can Be Converted with Doorstops: The notion that adding larger doorstops can convert a standard door to a fire door is incorrect. Fire doors must undergo stringent testing and adhere to specific industry standards.
  6. Any Lock Can Be Used: It is falsely believed that any metal lock is suitable for fire doors. In reality, fire doors need specially fire-rated locks that have been tested to endure high temperatures.

Summary

In conclusion, fire doors are a critical component of fire safety in both commercial and residential buildings. They are legally required in various building types to contain fires, protect escape routes, and save lives. Identifying key areas for their installation, ensuring professional fitting, and adhering to regular inspection schedules are essential steps in maintaining their effectiveness.

By understanding fire door ratings and matching them to your building’s decor, you can ensure both safety and aesthetic appeal. Dispelling common misconceptions about fire doors and staying compliant with regulations will help protect your property and its occupants. Fire safety is a collective responsibility, and taking these measures seriously can make a significant difference in the event of a fire.

For further information or to request a fire door inspection, contact our experienced team today. Don’t compromise on safety – invest in fire doors for your building and stay protected.

Frequently Asked Questions

Where are fire doors legally required?

Fire doors are legally required in non-domestic properties, commercial premises, public buildings, and multi-occupied residential buildings such as flats and HMOs.

How often should fire doors be inspected?

Fire doors should be inspected at least once every six months, with more frequent checks for doors in high-traffic areas and specific intervals for multi-occupied residential buildings. Regular inspection ensures safety and compliance.

Can a standard door be converted into a fire door with fireproof paint?

No, applying fireproof paint to a standard door does not meet recognised industry standards for converting it into a fire door.

What is the minimum fire-resistance rating for fire doors in commercial buildings?

In commercial buildings, fire doors must have a minimum fire resistance rating of 30 minutes, and they should also feature intumescent seals and self-closing mechanisms to meet safety standards.

Why is professional installation of fire doors important?

Professional installation of fire doors is important because it ensures they meet regulatory requirements, function correctly and provide effective fire protection.

Do ground-floor flats require fire doors?

Ground floor flats usually don’t need internal fire doors if there are accessible escape routes from each room, like a window or garden terrace. However, the front entrance door must be a fire door if it leads to a communal area, such as a corridor. Additionally, every flat in a block or HMO should have a fire door for shared spaces, regardless of the floor. Building regulations require fire doors between habitable rooms and hallways for flats above 4.5 meters, which doesn’t apply to ground-floor units. Thus, while internal fire doors aren’t generally needed in ground-floor flats, a fire-rated entrance door is necessary for access to communal areas.